GPB
Progressive grease distributor

BAOTN Lubrication

Price: Ask for more information.

Short description

● Quantitative fixed point lubrication.

● Product inspection, warranty for 1 years.

● Precision machining of piston.

● Traffic, digits can be customized.

Technical parameters of the GPB distributor

model grease distributor

1.Maximum working pressure: 25MPa

2.Minimum starting pressure: 1.4MPa

3.Standard displacement per port: 0.08ml/cy~0.56ml/cy.

4.Applicable lubricant range (at standard temperature): lubricating oil ≥ N68, grease NLGI 00O #~2#

5.Working environment temperature: -20℃~+60℃ (low temperature grease should be used at low temperature)

6.Plunger pair with mechanical cycle indicator Maximum cycle rate: 60cy/min.

7.Maximum circulation rate of plunger pair: 200cy/min.

8.Number of working pieces of each group of distributors: 3~10 pieces.

9.The number of lubrication points available for each group of distributors: 3~20 points.

10.The optimal diameter and length of the distributor output: Φ6mm long 1.2~3.5m; 8mm long 1.5~4.5m

11.Body material and coating: galvanized carbon steel surface.

Performance and characteristics

1.One-pipe for quantified cycle distribution.

2.Ejection capacity is changed based on specifications.

3.The quantity of link increased or decreased based quick ejection capacity.

4.Status of each ejection orifices represents status of all ejection capacity in case of any problems incurring ,the problem can be determined quickly.

Worksheet marker

worksheet marker

①⑤Distributor (slice) adjacent oil supply port upper and lower merge status mark:
U: Indicates that the oil outlet is merged with the oil supply port of the adjacent upper piece.
M: Indicates that the oil outlet is merged with the adjacent upper and lower oil feed ports at the same time.
D: Indicates that the oil supply port is merged with the adjacent lower plate oil supply port.
Blank: Indicates that it is not merged with the oil supply ports of the adjacent upper and lower parts.

②The oil supply specification code of the distributor (piece):

05——0.08ml/cy;
10——0.16ml/cy;
15——0.24ml/cy;
20——0.32ml/cy;
25——0.40ml/cy;
30——0.48ml/cy;
35——0.56ml/cy.

③The combined status mark of the left and right oil supply ports of the distributor (piece):
S: Indicates that the left and right oil feed ports of the film are combined.
Blank: Indicates that the left and right ports are not merged.

④Distributor (piece) to oil port status mark:
T: Indicates that the left and right sides of the film are provided with oil supply ports.
Z: Indicates that the film has no oil supply port.
L: Indicates that the chip has a single outlet, and the oil supply port is set on the left side.
R: Indicates that the chip has a single outlet, and the oil supply ort is set on the right side.

⑥Cycle indicator assembly position:
L: Indicates that the piece is equipped with an indicator and is installed at the left end of the piece.
R: Indicates that the sheet is provided with an indicator and is mounted on the right end of the sheet.
Blank: Indicates that there is no indicator for this slice